Skip to content

Upgrade firmware ​

This article mainly describes how to upgrade the firmware for the SKYE2 airspeed.

Before operation ​

Set controller parameters ​

To upgrade the SKYE2 airspeed through the controller, you need to set the following parameters in the entire parameter table of Mission plannerd ground station:

For smart controllers using STMF7XX/STMH7XX as CPU:

  • CAN_SLCAN_CPORT set to 1
  • Serial7_Protocol set to 22
  • Reboot the smart controller

说明

These controllers will have two usb driver ports in AP4.0/AP4.0 firmware, one is the smart controller mavlink output port, and the other is the slcan port; if there are no two ports, please uninstall the driver and reinstall it.

For smart controllers using STMF4xx as CPU:

  • CAN_SLCAN_CPORT set to 1
  • CAN_SLCAN_TIMEOUT set to 130000
  • CAN_SLCAN_SERNUM set to 0
  • Please do not reboot the smart controller until the upgrade is complete

说明

STM32F4 does not support dual virtual USB ports, so the version of the smart controller below FMU v5 (not included) can only be used for SLCAN by closing MAVlink transmission; after the above settings, USB will stop outputting mavlink data and convert it to SCLAN port; MAVlink will be restored after restarting transmission.

Firmware Upgrade ​

Upgrade with Dronecan GUI TOOL software

Droncan GUI

  • Select the device port corresponding to slcan and click "ok"
slcan
  • Click "√"; then double-click on the device information (marked in Figure 2 below)
slcan
  • Click "update firmware", the message box will pop up "yes"

  • The mode/heakth/uptime entry becomes "SOftware_update" slcan

  • Waiting for firmware write to complete

slcan