Mouse cursor moves erratically and communication fails after connecting the radio
Disconnect power from the USB side first, then power the other end. If data arrives at the USB port during startup, the system may identify the radio as a mouse device.
The indicator turns off and the radio stops working
The power supply is insufficient. Provide more than 2 A and use a separate supply for the USB side; a V5+ controller can power the radio directly.
Unable to establish a link
Airborne RSSI indicator stays on: the serial baud rate of the connected device does not match the radio. Change the device baud rate.
Airborne RSSI indicator flashes in sequence: the master was not found. Check that the network IP, serial baud rate, local address and target address match on both ends.
Is a separate power supply required?
The module draws significant current. A separate 12–60 V supply rated above 2 A is recommended. The ground unit can be powered from USB alone; CUAV controllers can power the air unit; if you use another controller, a separate power supply may be required.